Model Power Range Engine Cylinder Governor Type Displacement Fuel Consumption
L/H(100%)
Emission Standard Download
GW-M715
Prime:520kW / 650kVA
Standby:572kW / 715kVA
12V 2000 G25 12V/TCA ECU 23.9 140.0 N/A Request Specifications & Quotation
GW-M880
Prime:640kW / 800kVA
Standby:704kW / 880kVA
12V 2000 G65 12V/TCA ECU 23.9 167.0 N/A Request Specifications & Quotation
GW-M990
Prime:720kW / 900kVA
Standby:792kW / 990kVA
16V 2000 G25 16V/TCA ECU 31.8 191.0 N/A Request Specifications & Quotation
GW-M1100
Prime:800kW / 1000kVA
Standby:880kW / 1100kVA
16V 2000 G65 16V/TCA ECU 31.8 209.8 N/A Request Specifications & Quotation
GW-M1238
Prime:900kW / 1125kVA
Standby:990kW / 1238kVA
18V 2000 G65 18V/TCA ECU 35.8 240.5 N/A Request Specifications & Quotation
GW-M1800
Prime:1320kW / 1650kVA
Standby:1440kW / 1800kVA
12V 4000 G23 12V/TCA ECU 57.3 324.6 N/A Request Specifications & Quotation
GW-M2000
Prime:1470kW / 1838kVA
Standby:1600kW / 2000kVA
12V 4000 G63 12V/TCA ECU 57.3 361.9 N/A Request Specifications & Quotation
GW-M2250
Prime:1640kW / 2050kVA
Standby:1800kW / 2250kVA
16V 4000 G23 16V/TCA ECU 76.3 411.0 N/A Request Specifications & Quotation
GW-M2500
Prime:1840kW / 2300kVA
Standby:2000kW / 2500kVA
16V 4000 G63 16V/TCA ECU 76.3 446.8 N/A Request Specifications & Quotation
GW-M2750
Prime:2000kW / 2500kVA
Standby:2200kW / 2750kVA
20V 4000 G23 20V/TCA ECU 95.4 510.7 N/A Request Specifications & Quotation
GW-M3075
Prime:2200kW / 2750kVA
Standby:2460kW / 3075kVA
20V 4000 G63 20V/TCA ECU 95.4 556.0 N/A Request Specifications & Quotation
GW-M3300
Prime:2400kW / 3000kVA
Standby:2640kW / 3300kVA
20V 4000 G63L 20V/TCA ECU 95.4 592.0 N/A Request Specifications & Quotation
GW-M500
Prime:360kW / 450kVA
Standby:400kW / 500kVA
10V 1600 G1OF 10V/TCA ECU 17.5 101.8 EU ⅢA Request Specifications & Quotation
GW-M550
Prime:400kW / 500kVA
Standby:440kW / 550kVA
10V 1600 G2OF 10V/TCA ECU 17.5 108.9 EU ⅢA Request Specifications & Quotation
GW-M500
Prime:400kW / 500kVA
Standby:400kW / 500kVA
10V 1600 G70F 10V/TCA ECU 17.5 108.9 EU ⅢA Request Specifications & Quotation
GW-M563
Prime:410kW / 513kVA
Standby:450kW / 563kVA
10V 1600 G8OF 10V/TCA ECU 17.5 117.5 EU ⅢA Request Specifications & Quotation
GW-M650
Prime:470kW / 588kVA
Standby:520kW / 650kVA
12V 1600 G7OF 12V/TCA ECU 21.0 128.6 N/A Request Specifications & Quotation
GW-M713
Prime:520kW / 650kVA
Standby:570kW / 713kVA
12V 1600 G8OF 12V/TCA ECU 21.0 141.6 N/A Request Specifications & Quotation
GW-M650
Prime:480kW / 600kVA
Standby:520kW / 650kVA
12V 1600 G10F 12V/TCA ECU 21.0 117.0 N/A Request Specifications & Quotation
GW-M713
Prime:520kW / 650kVA
Standby:570kW / 713kVA
12V 1600 G2OF 12V/TCA ECU 21.0 128.6 N/A Request Specifications & Quotation
GW-M1375
Prime:1000kW / 1250kVA
Standby:1100kW / 1375kVA
18V 2000 G26F 18V/TCA ECU 40.2 242.2 N/A Request Specifications & Quotation
GW-M1400
Prime:1020kW / 1275kVA
Standby:1120kW / 1400kVA
18V 2000 G76F 18V/TCA ECU 40.2 285.0 N/A Request Specifications & Quotation
GW-M1500
Prime:1100kW / 1375kVA
Standby:1200kW / 1500kVA
12V40ODG14RF 12V/TCA ECU 57.2 278.0 N/A Request Specifications & Quotation
GW-M1813
Prime:1320kW / 1650kVA
Standby:1450kW / 1813kVA
12V400OG14F 12V/TCA ECU 57.2 342.2 N/A Request Specifications & Quotation
GW-M2000
Prime:1470kW / 1838kVA
Standby:1600kW / 2000kVA
12V4000G24F 12V/TCA ECU 57.2 419.4 N/A Request Specifications & Quotation
GW-M2250
Prime:1640kW / 2050kVA
Standby:1800kW / 2250kVA
16V4000G14F 16V/TCA ECU 76.3 433.3 N/A Request Specifications & Quotation
GW-M2375
Prime:1760kW / 2200kVA
Standby:1900kW / 2375kVA
16V4000G24F 16V/TCA ECU 76.3 471.1 N/A Request Specifications & Quotation
GW-M2750
Prime:2000kW / 2500kVA
Standby:2200kW / 2750kVA
20V4000G14F 20V/TCA ECU 95.4 508.9 N/A Request Specifications & Quotation
GW-M3000
Prime:2200kW / 2750kVA
Standby:2400kW / 3000kVA
20V4000G24F 20V/TCA ECU 95.4 574.4 N/A Request Specifications & Quotation
GW-M3300
Prime:2400kW / 3000kVA
Standby:2640kW / 3300kVA
20V4000G34F 20V/TCA ECU 95.4 599.1 N/A Request Specifications & Quotation
GW-M3500
Prime:2560kW / 3200kVA
Standby:2800kW / 3500kVA
20V4000G44F 20V/TCA ECU 95.4 653.0 N/A Request Specifications & Quotation
GW-M1800
Prime:1300kW / 1625kVA
Standby:1440kW / 1800kVA
12V4000G74F 12V/TCA ECU 57.2 377.6 N/A Request Specifications & Quotation
GW-M2000
Prime:1470kW / 1838kVA
Standby:1600kW / 2000kVA
12V4000G84F 12V/TCA ECU 57.2 419.6 N/A Request Specifications & Quotation
GW-M2250
Prime:1640kW / 2050kVA
Standby:1800kW / 2250kVA
16V4000G74F 16V/TCA ECU 76.3 471.1 N/A Request Specifications & Quotation
GW-M2500
Prime:1840kW / 2300kVA
Standby:2000kW / 2500kVA
16V4000G84F 16V/TCA ECU 76.3 526.5 N/A Request Specifications & Quotation
GW-M2750
Prime:2000kW / 2500kVA
Standby:2200kW / 2750kVA
20V4000G64F 20V/TCA ECU 95.4 554.0 N/A Request Specifications & Quotation
GW-M3000
Prime:2200kW / 2750kVA
Standby:2400kW / 3000kVA
20V40OOG74F 20V/TCA ECU 95.4 633.7 N/A Request Specifications & Quotation
GW-M3300
Prime:2400kW / 3000kVA
Standby:2640kW / 3300kVA
20V400OG84F 20V/TCA ECU 95.4 666.1 N/A Request Specifications & Quotation
GW-M3550
Prime:2580kW / 3225kVA
Standby:2840kW / 3550kVA
20V4000G94F 20V/TCA ECU 95.4 756.0 T2 Request Specifications & Quotation