Goodwind Perkins diesel generator set with red silent canopy

Perkins Diesel Generator Sets

GOODWIND Perkins diesel generator sets cover small premises through to larger industrial facilities, with engine families ranging from the 400 to the 4000 Series. The selection spans everyday backup needs and prime power duties across a broad range of loads.

Applications
  • Commercial premises
  • Agricultural facilities
  • Manufacturing plants
Perkins product video cover
Video coming soon
Product video is not available yet.

Compare generator set models

Review power ratings and engine details before downloading a model sheet or requesting a quotation.

Request a Quotation
Columns ▾
Model Power Range Engine Cylinder Governor Type Displacement Fuel Consumption
L/H(100%)
Emission Standard Download
GW-P10
Prime:7kW / 9kVA
Standby:8kW / 10kVA
403A-11G1 3L/NA M 1.1 2.5 N/A Request Specifications & Quotation
GW-P10
Prime:7kW / 9kVA
Standby:8kW / 10kVA
403D-11G 3L/NA M 1.1 2.6 T4I/EU ⅢA Request Specifications & Quotation
GW-P13
Prime:10kW / 13kVA
Standby:11kW / 14kVA
403A-15G1 3L/NA M 1.5 3.6 N/A Request Specifications & Quotation
GW-P13
Prime:10kW / 13kVA
Standby:11kW / 14kVA
403D-15G 3L/NA M 1.5 3.7 T4I/EU ⅢA Request Specifications & Quotation
GW-P17
Prime:12kW / 15kVA
Standby:13kW / 17kVA
403A-15G2 3L/NA M 1.5 4.1 N/A Request Specifications & Quotation
GW-P22
Prime:16kW / 20kVA
Standby:18kW / 22kVA
404A-22G1 4L/NA M 2.2 5.3 N/A Request Specifications & Quotation
GW-P22
Prime:16kW / 20kVA
Standby:18kW / 22kVA
404D-22G 4L/NA M 2.2 5.4 T4I/EU ⅢA Request Specifications & Quotation
GW-P30
Prime:22kW / 28kVA
Standby:24kW / 30kVA
404D-22TG 4L/TC E 2.2 7.1 T4I/EU ⅢA Request Specifications & Quotation
GW-P33
Prime:24kW / 30kVA
Standby:26kW / 33kVA
1103A-33G 3L/NA M 3.3 7.1 N/A Request Specifications & Quotation
GW-P50
Prime:36kW / 45kVA
Standby:40kW / 50kVA
1103A-33TG1 3L/TC M 3.3 10.7 N/A Request Specifications & Quotation
GW-P66
Prime:48kW / 60kVA
Standby:53kW / 66kVA
1103A-33TG2 3L/TC M 3.3 13.9 N/A Request Specifications & Quotation
GW-P72
Prime:52kW / 65kVA
Standby:58kW / 72kVA
1104A-44TG1 4L/TC M 4.4 14.8 N/A Request Specifications & Quotation
GW-P88
Prime:64kW / 80kVA
Standby:70kW / 88kVA
1104A-44TG2 4L/TC M 4.4 18.7 N/A Request Specifications & Quotation
GW-P110
Prime:80kW / 100kVA
Standby:88kW / 110kVA
1104C-44TAG2 4L/TCA E 4.4 22.6 T2/EU Ⅱ Request Specifications & Quotation
GW-P150
Prime:108kW / 135kVA
Standby:120kW / 150kVA
1106A-7OTG1 6L/TC M 7.0 30.2 N/A Request Specifications & Quotation
GW-P165
Prime:120kW / 150kVA
Standby:132kW / 165kVA
1106A-7OTAG2 6L/TCA M 7.0 32.2 N/A Request Specifications & Quotation
GW-P200
Prime:144kW / 180kVA
Standby:160kW / 200kVA
1106A-7OTAG3 6L/TCA M 7.0 40.2 N/A Request Specifications & Quotation
GW-P220
Prime:160kW / 200kVA
Standby:176kW / 220kVA
1106A-7OTAG4 6L/TCA E 7.0 44.7 N/A Request Specifications & Quotation
GW-P250
Prime:180kW / 225kVA
Standby:200kW / 250kVA
1506A-E88TAG2 6L/TCA ECU 8.8 50.0 N/A Request Specifications & Quotation
GW-P250
Prime:180kW / 225kVA
Standby:200kW / 250kVA
1206A-E7OTTAG2 6L/TCA ECU 7.0 51.0 N/A Request Specifications & Quotation
GW-P275
Prime:200kW / 250kVA
Standby:220kW / 275kVA
1206A-E7OTTAG3 6L/TCA ECU 7.0 56.9 N/A Request Specifications & Quotation
GW-P275
Prime:200kW / 250kVA
Standby:220kW / 275kVA
1506A-E88TAG3 6L/TCA ECU 8.8 56.0 N/A Request Specifications & Quotation
GW-P339
Prime:240kW / 300kVA
Standby:271kW / 339kVA
1706A-E93TAG1 6L/TCA ECU 9.3 62.0 N/A Request Specifications & Quotation
GW-P383
Prime:278kW / 348kVA
Standby:306kW / 383kVA
1706A-E93TAG2 6L/TCA ECU 9.3 70.4 N/A Request Specifications & Quotation
GW-P400
Prime:280kW / 350kVA
Standby:320kW / 400kVA
2206C-E13TAG2 6L/TCA ECU 12.5 71.0 T2/EU Ⅱ Request Specifications & Quotation
GW-P450
Prime:320kW / 400kVA
Standby:360kW / 450kVA
2206C-E13TAG3 6L/TCA ECU 12.5 81.0 T2/EU Ⅱ Request Specifications & Quotation
GW-P500
Prime:360kW / 450kVA
Standby:400kW / 500kVA
2506C-E15TAG1 6L/TCA ECU 15.2 95.0 T2/EU Ⅱ Request Specifications & Quotation
GW-P550
Prime:400kW / 500kVA
Standby:440kW / 550kVA
2506C-E15TAG2 6L/TCA ECU 15.2 106.0 T2/EU Ⅱ Request Specifications & Quotation
GW-P650
Prime:472kW / 590kVA
Standby:520kW / 650kVA
2806C-E18TAG1A 6L/TCA ECU 18.0 123.0 T2/EU Ⅱ Request Specifications & Quotation
GW-P700
Prime:520kW / 650kVA
Standby:560kW / 700kVA
2806A-E18TAG2 6L/TCA ECU 18.0 132.0 N/A Request Specifications & Quotation
GW-P825
Prime:600kW / 750kVA
Standby:660kW / 825kVA
4006-23TAG2A 6L/TCA E 22.9 157.0 N/A Request Specifications & Quotation
GW-P900
Prime:640kW / 800kVA
Standby:720kW / 900kVA
4006-23TAG3A 6L/TCA E 22.9 172.0 N/A Request Specifications & Quotation
GW-P1000
Prime:720kW / 900kVA
Standby:800kW / 1000kVA
4008TAG1A 8L/TCA E 30.6 212.0 N/A Request Specifications & Quotation
GW-P1100
Prime:800kW / 1000kVA
Standby:880kW / 1100kVA
4008TAG2A 8L/TCA E 30.6 220.0 N/A Request Specifications & Quotation
GW-P1250
Prime:900kW / 1125kVA
Standby:1000kW / 1250kVA
4008-3OTAG3 8L/TCA E 30.6 244.5 N/A Request Specifications & Quotation
GW-P1385
Prime:1000kW / 1250kVA
Standby:1108kW / 1385kVA
4012-46TWG2A 12V/TW E 45.4 259.0 N/A Request Specifications & Quotation
GW-P1600
Prime:1200kW / 1500kVA
Standby:1280kW / 1600kVA
4012-46TAG2A 12V/TCA E 45.4 301.0 N/A Request Specifications & Quotation
GW-P1815
Prime:1320kW / 1650kVA
Standby:1452kW / 1815kVA
4012-46TAG3A 12V/TCA E 45.4 370.0 N/A Request Specifications & Quotation
GW-P2000
Prime:1480kW / 1850kVA
Standby:1600kW / 2000kVA
4016TAG1A 16V/TCA E 61.0 383.0 N/A Request Specifications & Quotation
GW-P2250
Prime:1600kW / 2000kVA
Standby:1800kW / 2250kVA
4016TAG2A 16V/TCA E 61.0 434.0 N/A Request Specifications & Quotation
GW-P2500
Prime:1800kW / 2250kVA
Standby:2000kW / 2500kVA
4016-61TRG3 16V/TW E 61.0 473.0 N/A Request Specifications & Quotation