Global leader in power generation equipment.
Global high-end power solutions provider.
French engine manufacturer established in 1918.
One of the largest domestic engine manufacturers in China.
View MITSUBISHI generator set configurations.
Japanese company focused on small and medium engines.
A well-known Chinese manufacturer of marine power systems.
A globally recognised manufacturer of diesel engines for power generation and industrial applications.
A century-old Swedish enterprise renowned for safety and reliability.
China's leading power system provider.
Diesel engines for power generation.
An outstanding pioneer in smart new power.
One of the largest production bases for small-power diesel engines in China.
Let the world hear the voice of China.
20+ years of industry experience in generator sets.
Manufacturing equipment, inspection and testing documented in our company profile.
A trusted provider of power generation solutions.
Explore original certification, patent and cooperation documents.
Explore factory updates, generator projects, exhibitions and practical power industry insights.
Our people are central to our competitiveness and development.
Containerized generator sets for outdoor industrial power applications.
Open-frame generator sets with an integrated base fuel tank.
Canopy designs for equipment protection, space constraints and noise control.
Mobile generator sets for temporary power at changing worksites.
Generator sets for onboard auxiliary power and emergency electrical supply.
Mobile lighting for construction sites, night work and emergency operations.
Vehicle-mounted generator sets for temporary power and emergency response.
Industrial generator sets for projects with high-voltage power distribution.
GOODWIND Yuchai diesel generator sets cover a wide power spectrum, from four-cylinder configurations to larger V-engine models. The range provides choices for commercial backup, industrial prime power and larger facility loads, with different engine families serving different project scales.
GOODWIND Yuchai gas generator sets include four-cylinder and six-cylinder engine configurations for on-site electricity generation. The range spans smaller facility loads and larger industrial requirements, with selection guided by the available gas supply, fuel composition and intended operating demand.
Review power ratings and engine details before downloading a model sheet or requesting a quotation.
| Generator model | Power ratings | Engine model | Cylinders / arrangement / aspiration | Speed governing type | Displacement (L) | Fuel consumption L/h · 100% load |
Emission information | Download | Explore | |
|---|---|---|---|---|---|---|---|---|---|---|
| GW-Y24 | Prime:18kW / 22kVA Standby:19kW / 24kVA |
YC4V35-D20 | 4L/NA | M | 2.5 | 6.5 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y33 | Prime:24kW / 30kVA Standby:26kW / 33kVA |
YC4V45Z-D20 | 4L/TC | M | 2.5 | 8.1 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y41 | Prime:30kW / 38kVA Standby:33kW / 41kVA |
YC4V55Z-D20 | 4L/TC | M | 2.5 | 10.2 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y44 | Prime:32kW / 40kVA Standby:35kW / 44kVA |
YC4D60-D25 | 4L/NA | E | 3.9 | 10.5 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y69 | Prime:50kW / 63kVA Standby:55kW / 69kVA |
YC4D90Z-D25 | 4L/TC | E | 4.8 | 15.3 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y83 | Prime:60kW / 75kVA Standby:66kW / 83kVA |
YC4A100Z-D25 | 4L/TC | E | 4.8 | 17.9 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y110 | Prime:80kW / 100kVA Standby:88kW / 110kVA |
YC4A140L-D25 | 4L/TW | E | 4.8 | 24.6 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y138 | Prime:100kW / 125kVA Standby:110kW / 138kVA |
YC4A180L-D20 | 4L/TW | E | 4.8 | 29.9 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y138 | Prime:100kW / 125kVA Standby:110kW / 138kVA |
YC6B180L-D20 | 6L/TCA | E | 6.9 | 28.5 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y165 | Prime:120kW / 150kVA Standby:132kW / 165kVA |
YC6B205L-D20 | 6L/TCA | E | 6.9 | 34.9 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y200 | Prime:150kW / 188kVA Standby:160kW / 200kVA |
YC6A245L-D21 | 6L/TCA | E | 7.3 | 40.1 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y275 | Prime:200kW / 250kVA Standby:220kW / 275kVA |
YC6MK350L-D20 | 6L/TCA | E | 10.3 | 57.2 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y344 | Prime:250kW / 313kVA Standby:275kW / 344kVA |
YC6MK420L-D20 | 6L/TCA | E | 10.3 | 69.1 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y413 | Prime:300kW / 375kVA Standby:330kW / 413kVA |
YC6MJ500L-D21 | 6L/TCA | E | 11.7 | 81.4 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y500 | Prime:360kW / 450kVA Standby:400kW / 500kVA |
YC6T6OOL-D22 | 6L/TCA | E | 16.4 | 98.2 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y550 | Prime:400kW / 500kVA Standby:440kW / 550kVA |
YC6T660L-D20 | 6L/TCA | E | 16.4 | 110.1 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y22 | Prime:16kW / 20kVA Standby:18kW / 22kVA |
YCDV254FHZ-25 | 4L/TC | ECU | 2.5 | 5.3 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y28 | Prime:20kW / 25kVA Standby:22kW / 28kVA |
YCDV254FHZ-35 | 4L/TC | ECU | 2.5 | 6.6 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y33 | Prime:24kW / 30kVA Standby:26kW / 33kVA |
YCDV254FHZ-40 | 4L/TC | ECU | 2.5 | 8.1 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y41 | Prime:30kW / 38kVA Standby:33kW / 41kVA |
YCDV254HHZ-50 | 4L/TC | ECU | 2.5 | 10.1 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y55 | Prime:40kW / 50kVA Standby:44kW / 55kVA |
YCD4V33H6-75 | 4L/TCA | ECU | 2.5 | 12.1 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y62 | Prime:45kW / 56kVA Standby:50kW / 62kVA |
YC4D80-D34 | 4L/TC | ECU | 4.2 | 14.8 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y69 | Prime:50kW / 63kVA Standby:55kW / 69kVA |
YC4D90-D34 | 4L/TCA | ECU | 4.2 | 17.0 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y83 | Prime:60kW / 75kVA Standby:66kW / 83kVA |
YC4D105-D34 | 4L/TC | ECU | 4.2 | 19.6 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y110 | Prime:80kW / 100kVA Standby:88kW / 110kVA |
YC4D140-D31 | 4L/TCA | ECU | 4.2 | 25.6 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y125 | Prime:90kW / 113kVA Standby:100kW / 125kVA |
YC4D155-D31 | 4L/TCA | ECU | 4.2 | 27.6 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y110 | Prime:80kW / 100kVA Standby:88kW / 110kVA |
YC4A140-D30 | 4L/TCA | ECU | 4.8 | 25.4 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y125 | Prime:90kW / 113kVA Standby:100kW / 125kVA |
YC4A155-D30 | 4L/TCA | ECU | 4.8 | 27.1 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y125 | Prime:90kW / 113kVA Standby:100kW / 125kVA |
YC4A165-D30 | 4L/TCA | ECU | 4.8 | 28.3 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y150 | Prime:110kW / 138kVA Standby:120kW / 150kVA |
YC4A190-D30 | 4L/TCA | ECU | 4.8 | 31.9 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y165 | Prime:120kW / 150kVA Standby:132kW / 165kVA |
YCD6Q23H8-210 | 6L/TC | ECU | 7.4 | 35.3 | CN NR Ⅱ | Request Specifications & Quotation | ||
| GW-Y220 | Prime:160kW / 200kVA Standby:176kW / 220kVA |
YCD6Q33H6-260 | 6L/TCA | ECU | 7.42 | 45.5 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y165 | Prime:120kW / 150kVA Standby:132kW / 165kVA |
YC6A205-D30 | 6L/TCA | ECU | 7.255 | 35.3 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y188 | Prime:140kW / 175kVA Standby:150kW / 188kVA |
YC6A230-D30 | 6L/TCA | ECU | 7.255 | 39.8 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y200 | Prime:150kW / 188kVA Standby:160kW / 200kVA |
YC6A245-D30 | 6L/TCA | ECU | 7.255 | 41.8 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y220 | Prime:160kW / 200kVA Standby:176kW / 220kVA |
YC6A275-D30 | 6L/TCA | ECU | 7.255 | 47.1 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y275 | Prime:200kW / 250kVA Standby:220kW / 275kVA |
YC6MK350-D30 | 6L/TCA | ECU | 10.34 | 57.5 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y344 | Prime:250kW / 313kVA Standby:275kW / 344kVA |
YC6MK420-D30 | 6L/TCA | ECU | 10.34 | 68.3 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y375 | Prime:280kW / 350kVA Standby:300kW / 375kVA |
YC6MK450-D30 | 6L/TCA | ECU | 10.34 | 72.6 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y413 | Prime:300kW / 375kVA Standby:330kW / 413kVA |
YC6MJ500-D30 | 6L/TCA | ECU | 11.73 | 82.0 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y440 | Prime:320kW / 400kVA Standby:352kW / 440kVA |
YC6MJ540-D30 | 6L/TCA | ECU | 11.73 | 87.9 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y500 | Prime:360kW / 450kVA Standby:400kW / 500kVA |
YC6MJ600-D30 | 6L/TCA | ECU | 11.73 | 97.3 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y413 | Prime:300kW / 375kVA Standby:330kW / 413kVA |
YC6K500-D31 | 6L/TCA | ECU | 12.16 | 83.0 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y413 | Prime:300kW / 375kVA Standby:330kW / 413kVA |
YC6K500-D30 | 6L/TCA | ECU | 12.16 | 83.0 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y440 | Prime:320kW / 400kVA Standby:352kW / 440kVA |
YC6K520-D30 | 6L/TCA | ECU | 12.16 | 89.0 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y500 | Prime:360kW / 450kVA Standby:400kW / 500kVA |
YC6K600-D30 | 6L/TCA | ECU | 12.94 | 100.0 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y550 | Prime:400kW / 500kVA Standby:440kW / 550kVA |
YC6K660-D30 | 6L/TCA | ECU | 12.94 | 103.0 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y550 | Prime:400kW / 500kVA Standby:440kW / 550kVA |
YC6T660-D31 | 6L/TCA | ECU | 16.35 | 113.8 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y625 | Prime:450kW / 563kVA Standby:500kW / 625kVA |
YC6TD780-D31 | 6L/TCA | ECU | 19.6 | 130.8 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y688 | Prime:500kW / 625kVA Standby:550kW / 688kVA |
YC6TD840-D31 | 6L/TCA | ECU | 19.6 | 143.2 | CN NR Ⅲ | Download | ||
| GW-Y750 | Prime:550kW / 688kVA Standby:600kW / 750kVA |
YC6TD900-D31 | 6L/TCA | ECU | 19.6 | 154.3 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y813 | Prime:600kW / 750kVA Standby:650kW / 813kVA |
YC6TD1000-D30 | 6L/TCA | ECU | 19.6 | 166.4 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y888 | Prime:650kW / 813kVA Standby:710kW / 888kVA |
YC6TH1070-D31 | 6L/TCA | ECU | 28.14 | 177.2 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y1000 | Prime:720kW / 900kVA Standby:800kW / 1000kVA |
YC6TH1220-D31 | 6L/TCA | ECU | 28.14 | 199.1 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y1100 | Prime:800kW / 1000kVA Standby:880kW / 1100kVA |
YC6TH1320-D31 | 6L/TCA | ECU | 28.14 | 216.4 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y1250 | Prime:900kW / 1125kVA Standby:1000kW / 1250kVA |
YC6C1520-D31 | 6L/TCA | ECU | 39.58 | 253.3 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y1375 | Prime:1000kW / 1250kVA Standby:1100kW / 1375kVA |
YC6C1660-D31 | 6L/TCA | ECU | 39.58 | 276.8 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y1375 | Prime:1000kW / 1250kVA Standby:1100kW / 1375kVA |
YC12VTD1680-D30 | 12V/TW | ECU | 39.2 | 259.1 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y1500 | Prime:1100kW / 1375kVA Standby:1200kW / 1500kVA |
YC12VTD1830-D30 | 12V/TW | ECU | 39.2 | 285.2 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y1650 | Prime:1200kW / 1500kVA Standby:1320kW / 1650kVA |
YC12VTD2000-D30 | 12V/TW | ECU | 39.2 | 319.7 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y1650 | Prime:1200kW / 1500kVA Standby:1320kW / 1650kVA |
YC12VC2070-D31 | 12V/TW | ECU | 79.17 | 339.2 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y1800 | Prime:1320kW / 1650kVA Standby:1440kW / 1800kVA |
YC12VC2270-D31 | 12V/TW | ECU | 79.17 | 370.6 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y2000 | Prime:1500kW / 1875kVA Standby:1600kW / 2000kVA |
YC12VC2510-D31 | 12V/TW | ECU | 79.17 | 416.5 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y2250 | Prime:1700kW / 2125kVA Standby:1800kW / 2250kVA |
YC12VC2700-D31 | 12V/TW | ECU | 79.17 | 441.9 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y2500 | Prime:1800kW / 2250kVA Standby:2000kW / 2500kVA |
YC12VC3000-D30 | 12V/TW | ECU | 79.17 | 505.9 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y1800 | Prime:1320kW / 1650kVA Standby:1440kW / 1800kVA |
YC16VTD2270-D30 | 16V/TW | ECU | 52.26 | 374.4 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y2000 | Prime:1500kW / 1875kVA Standby:1600kW / 2000kVA |
YC16VTD2510-D30 | 16V/TW | ECU | 52.26 | 412.5 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y2250 | Prime:1700kW / 2125kVA Standby:1800kW / 2250kVA |
YC16VTD2700-D30 | 16V/TW | ECU | 52.26 | 432.5 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y2420 | Prime:1760kW / 2200kVA Standby:1936kW / 2420kVA |
YC16VC3000-D31 | 16V/TW | ECU | 105.56 | 493.9 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y2750 | Prime:2000kW / 2500kVA Standby:2200kW / 2750kVA |
YC16VC3300-D31 | 16V/TW | ECU | 105.56 | 543.2 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y3000 | Prime:2200kW / 2750kVA Standby:2400kW / 3000kVA |
YC16VC3600-D31 | 16V/TW | ECU | 105.56 | 594.4 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y3300 | Prime:2400kW / 3000kVA Standby:2640kW / 3300kVA |
YC16VC4000-D31 | 16V/TW | ECU | 105.56 | 673.9 | CN NR Ⅲ | Request Specifications & Quotation | ||
| GW-Y2500D5 | Prime:2000kW / 2500kVA Standby:2200kW / 2750kVA |
VC16VC3000-D31 | 16V | E | 105.56 | 479.3 | N/A | Download | ||
| GW-Y2500D5 | Prime:1800kW / 2250kVA Standby:2000kW / 2500kVA |
YC20VTD3000-D30 | 20V | E | 65.33 | 460.7 | N/A | Download |